Photo taken by: Ivory A. Red |
It is stated in NBCP Chapter VI- Fire Resistive Requirements in Counstruction Section 603 Fire Resistive Standards that all materials of construction, and type of materials and assemblies or combinations thereof shall conform to the following fire-resistive ratings: for solid concrete wall partitions must be in minimum of 175 millimeters.
The wall with the red color ellipse in the photo above is where Section 603 is applied to this residential interior. The solid concrete wall partition has reached the minimum thickness of 175 millimeters. The wall is adjacent to the bedroom and the kitchen in which the fire resistive thickness of the wall is important since using of fire and cooking happens in the kitchen.
Photo taken by: Kyle Ocoy |
It is also in section 603 that states that the minimum thickness for solid concrete slab is 150 millimeters.
The photo above specifically those in red ellipses are the solid concrete slabs in the unfinished residential interior. The solid concrete slabs has exceeded the minimum thickness of 150 millimeters but what is important that it does not go below the required minimum thickness to ensure the safety of the occupants.
The section 707 states that the size of an automobile (car) parking slot must be computed at 2.50 meters by 55.00 meters for perpendicular or diagonal parking and at 2.15 meters buy 6.00 meters for parallel parking
The photo above shows the standard size of an automobile parking slot.
It is stated in NBCP Chapter VII- Classification and General Requirements of All Buildings By Use or Occupancy Section 601 Occupancy Classified that a proposed buildings for construction shall be identified according to their use or the Character of its occupancy and shall be classified..
Building Classification: Group A - Division 2
Example above is an apartment complex that has numerous units within it(more than 2). the occupants that live here are permanent.
Image source: http://cduh.com.ph |
Building Classification: Group D - Institutional
In Section 704. Location Property, It states that No building shall be constructed unless it adjoins or has direct access to a public space, yard or street on at least on of its sides.
Image source: www.beyondcebu.com |
Quest Hotel is located in Archiboshop Reyes Ave. Cebu City, Cebu. As soon as you step out of the hotel, You can see the busy highway. It is also near the city center; shopping, sightseeing, restos and bars nearby. It is also easily accessible by car and parking area and also near public transit.
GUIDELINES ON EASEMENTS, VIEW CORRIDORS/SIGHT LINES, STREETS/ROAD RIGHT-OFWAY (RROW), SIDEWALKS, ARCADES, BASEMENTS, LOTS, AND PUBLIC BUILDINGS/STRUCTURES
C. STREETS/ROAD RIGHT-OF-WAY (RROW)
1. General. No building shall be constructed unless it adjoins or has direct access to public space, yard or street/road on at least one (1) of its sides. All buildings shall face a public street, alley or a road, which has been duly approved by the proper authorities for residential, institutional, commercial and industrial groups. This means that all houses or building structures shall face a public street or road.
FAQ.PH |
RIZAL MONUMENT IN LUNETA PARKB. VIEW CORRIDORS AND/OR SIGHT LINES 1. Preservation of View Corridors and/or Sight Lines To dignify very important public or historical/culture buildings/structures, all forms of commercial signs intruding into RROW leading to or away from such buildings/structures shall not be allowed. In this part building code it states that no building or commercial signs must not block a certain historical or cultural buildings or structures.
Image source: myphilippinelife.com |
Section 903, number 2 states that "all buildings located in areas where there are no available sanitary sewerage system shall dispose their sewage to “Imhoff” or septic tank and subsurface absorption field or to a suitable waste water treatment plant or disposal system in accordance with the Code on Sanitation of the Philippines and the Revised National Plumbing Code of the Philippines. "
The photo above shows Chapter IX Sanitation Section 903 in NBCP in action. The first photo shows how the construction workers excavate the soil and put the base of the septic tank to which where the waste goes. On second photo shows cementing and covering the top of the septic tank. Placements of the septic tank should be away from the facade of the building but must be accessible to the septic truck by the time they collect the waste.
Photo taken by: Ivory A. Red |
Chapter IX Sanitation Section 904 Storm Drainage system states that "Rainwater drainage shall not discharge to the sanitary sewer system"
It is clearly shown in the photo above that street has provided rainwater drainage to avoid rainwater to get stagnant and cause flood. the rainwater drainage is important especially to those establishments that are located along the road to avoid flood getting inside the building. Rainwater drainage should not discharge to the sanitary sewer system as it may cause overflowing.
This new blog post is well organized. you can freely understand the context and the meaning. The explanations are short but straight to the point.
ReplyDeleteThis comment has been removed by the author.
ReplyDeleteThis comment has been removed by the author.
ReplyDelete(http://ppgsix.weebly.com/) Group 6
ReplyDeleteThis blog post is great! easy to understand, very well organized and concise. Good job on the photos cause they really helped us readers understand the topics more. Careful on the typos and spacing though but overall, this blog post is quite good.
The King Casino | Ventureberg
ReplyDeleteDiscover the ventureberg.com/ rise and fall of ford escape titanium the goyangfc king casino, one of the world's largest herzamanindir.com/ The Casino is operated by jancasino the King Casino Group. You can